Hydrostatic & Pressure Vessel Testing Fluids
Hydrostatic testing fluids are used to assure the integrity of pipes, valves, and other parts that need hold pressures accurately with no leaks or structural integrity. The pressure vessel testing fluid used in these tests needs to assure that no rust or corrosion is left when the fluid is removed while at the same time leaving a microscopic or unnoticeable layer of chemical.
Contact Us Today:
1 (800) 244-9004
Features & Benefits
Characteristics
Pro-Tek HTF is a synthetic water-soluble fluid designed for hydrostatic testing of tubular products. Specially designed for large sumps like Taylor Wilson automatic testers, Pro-Tek HTF contains synthetic lubricity additives, corrosion inhibitors and stabilizers for optimum performance. The product eliminates and inhibits any bacteria and/or fungus growth.
Benefits
- Superior Lubrication
- Excellent Rust Protection
- Improved Safety
- Forms a stable diluted system
- Cost Effective
- Bio-Resistant
Properties
Appearance | Clear and/or Dyed Blue |
Diluted Appearance | Water White or Blue |
Solubility | 100 % Soluble |
Odor | Mild Industrial |
Specific Gravity | 1.01 |
Concentrate pH | 9.3 |
pH, 5 % dilution | 9.3 |
Freeze/Thaw Cycles | Passed 3x |
Hard water Tolerance | Excellent |
Questions About Our Products?
Contact Our Sales Engineers.
Our Sales Engineers are widely regarded as the most competent and responsive in the business: they know the material, the workpiece, the tools and the fluids that you need to make it right. Together with our Field Application Engineers, they’re available with on-site assistance and technical support when you need it.
Contact Us Today:
1 (800) 244-9004
Additional Details
Metal Compatibality
- Steel
- Inconel
- Composites
- Cast Iron
- Aluminum
- High Carbon
- Stainless Steel
- Copper
- Plastics
- Titanium
- Brass
- Nickel Alloys
Health & Safety
See the most recent SDS which is available directly from
ValCOOL, your local representative or authorized
distributor. ValCOOL uses only raw materials not listed
as carcinogenic by IRAC.
Refractive Index Monitoring
4.3 x multiplier
Percentage | Ratio | Refractometer Reading |
3 | 33 to 1 | 0.7 |
5 | 19 to 1 | 1.2 |
10 | 9 to 1 | 2.3 |
15 | 5 to 1 | 3.4 |
Fluid compatibility and machinability should always be tested first.